| 1. Match the disperser to the sample | Consider sample volume, viscosity, solids loading, and whether the material is handled as a liquid suspension or dry powder. Confirm that the disperser and vessel can process the required sample volume. | Sample volume (mL); solids concentration (% w/w); liquid viscosity (mPa·s); vessel dimensions (mm). | Use a representative sample and keep its preparation consistent. Report the sample and dispersion conditions with the particle-size results. |
| 2. Check the operating range | Compare the instrument’s rated frequency and power with the application. Nominal power alone does not establish the acoustic energy delivered to the sample; vessel geometry, probe position, and sample properties also matter. | Rated frequency (kHz); rated power (W); operating amplitude (%); treatment time (s); pulse settings, if used. | Record the settings for each measurement. Evaluate whether D10, D50, and D90 reach a stable result as the treatment conditions are adjusted. |
| 3. Choose suitable probe and vessel geometry | Select a probe compatible with the sample volume and vessel. Provide clearance from vessel walls and the bottom, and use a repeatable probe position to reduce variation between runs. | Probe-tip diameter (mm); immersion depth (mm); probe-to-wall clearance (mm); vessel material and dimensions. | Keep geometry and positioning unchanged between replicates. Compare the particle-size distributions, not just a single median value. |
| 4. Manage heating and sample stability | Ultrasonic treatment can heat a sample. Check whether temperature changes, evaporation, or chemical instability could affect the material or the measurement. | Initial and final temperature (°C); treatment duration (s); cooling method; visible changes, if any. | Use a controlled temperature procedure where needed. Confirm that additional treatment does not cause a continuing shift in D10, D50, or D90. |
| 5. Define a reproducible dispersion procedure | Establish a consistent sequence for sample addition, wetting, mixing, ultrasonic treatment, and transfer. Select a compatible dispersing liquid and any additives based on the sample’s chemistry. | Dispersant composition; sample mass (g) or volume (mL); mixing time (s); treatment time (s); replicates (n). | Document the preparation procedure and repeat measurements under the same conditions. Do not treat one set of settings as suitable for every material. |
| 6. Check for over-dispersion or particle damage | More ultrasonic energy is not always better. Excessive treatment may break fragile particles or alter agglomerates that are relevant to the intended application. | Treatment time (s); amplitude (%); temperature (°C); changes in distribution with treatment. | Run a treatment-time check. A stable distribution can indicate adequate dispersion, while a continuing decrease in size may warrant investigation for particle breakage. |
| 7. Verify results using laser diffraction principles | For measurements made by laser diffraction, follow the instrument method and applicable requirements of ISO 13320:2020. The standard describes measurement principles and procedures; it does not prescribe a universal particle-size target for every material. | D10, D50, and D90 (µm); distribution basis; optical model and refractive-index inputs; obscuration or concentration setting; replicate results. | D10, D50, and D90 are the particle diameters below which 10%, 50%, and 90% of the reported cumulative distribution fall, respectively. State the distribution basis and measurement conditions when reporting them. |